PTX

Delivery Time: not specified

Standard-screw-in resistance thermometer Pt100 with and without neck tube for EX-range

  • ATEX-approval
  • Large selection of variants
  • Measuring insert can be changed separately

 

Description

Fundamentals of ACS Universal resistance thermometer are standardized, high-quality platinum RTDs of a nominal resistance of 100 ohms at 0 ° C, tolerance classes A, B, 1/3B (AA) – in accordance with DIN EN / IEC 60751st.

ACS Pt100 probes have a high accuracy and reproducibility are ​​extremely reliable.

PTX-resistance thermometers are approved for gas and dust explosion requirements, and are generally delivered with exchangeable measuring insert Pt100. Thus, the actual sensor may be removed from the probe tube and possibly replaced without draining the pipe or the container. This saves costs and avoids loss of production.

Ex_Zulassung V4A Prozeßsicherheit Prozesstemperatur_400 Hochtemperatur_600
ATEX classes ATEX II 1 G Ex ia IIC T6…T1 Ga
ATEX II 1 D Ex ia IIIC Tx°C Da
Measurement accuracy IEC 60751
Accuracy class B – type B T = -50°C…+400°C ≤ ±(0,3K + 0,005 * |T|)
Accuracy class A – type A T = -50°C…+250°C ≤ ±(0,15K + 0,002 * |T|)
T = +250°C…+400°C ≤ ±(0,3K + 0,005 * |T|)
Accuracy class AA – type C T = 0°C…+100°C ≤ ±(0,1K + 0,0017 * |T|)
T = -50°C…0°C / +100°C…+250°C ≤ ±(0,15K + 0,002 * |T|)
T = +250°C…+400°C ≤ ±(0,3K + 0,005 * |T|)
type S – accuracy class B T = -200°C…+600°C ≤ ±(0,3K + 0,005 * |T|)
type S – accuracy class A T = -200°C…+600°C ≤ ±(0,15K + 0,002 * |T|)
type S – accuracy class AA T = -50°C…+250°C ≤ ±(0,1K + 0,0017 * |T|)
T = -50°C…0°C /+250°C…+600°C ≤ ±(0,15K + 0,002 * |T|)
Materials
Protection tube
(medium contact)
Steel 1.4404 (AISI 316L)
Steel 1.4571 (AISI 316Ti)
Process connection
(medium contact)
Steel 1.4404 (AISI 316L)
Steel 1.4571 (AISI 316Ti)
Neck tube CrNi-Steel
Connection housing CrNi-Steel
Lacquered aluminum
PP – polypropylene
POM – polyoxymethylene (Delrin®)
Environmental conditions
Ambient temperature -40°C…+130°C (limitation through material
see technical manual)
Process temperatures -50°C…+600°C (limitation through category)
Process pressure ranges -1bar…+60bar (depending on process connection version)
Protection class IP67 (EN/IEC 60529)

Documentation german

User manual
Datasheet
Wiring diagram

Documentation english

User manual
Datasheet

Product configurator