Precont® PS4SM

Delivery Time: not specified

Digital pressure switch with metall membrane

  • Metal cell for up to 1000bar
  • Analouge and up to 2 switching points
  • Housing and display turnable

 

Description

Due to the device construction as well as the availability of industrial standard process connections the device Precont® PS4SM is especially suitable for the use for machinery and plant engineering, air-conditioning and refrigeration plant engineering, hydraulic and pneumatic systems, process industry and environmental technology.

The pressure switch is suitable for demanding measuring requirements.

Due to its high accuracy and the high flexibility of configuration, the device can be suited a wide variety of applications.

The pressure switch with front-flush diaphragm has been specifically designed for the measurement of viscous, paste-like, adhesive, crystallizing, particle-laden and contaminated media, which would clog the pressure channel of conventional process connections.

The front-flush diaphragm is completely welded with the process connection and supplied with a positive seal. A reliable, dead-space free sealing between the process connection and the process adapter resp. measuring medium is thus assured.

The robust design and the high-quality workmanship turns the device into a very high quality product, which even the most adverse environmental conditions cannot affect, whether the lowest temperatures when used outdoors, extreme shock and vibration or aggressive media.

A captive laser marking of the type label ensures the identifiability throughout the entire lifetime of the device.

Obviously is the optional marking of a measurement point designation resp. TAG, a customer label or of a neutral type label, of course also per laser marking.

A LABS-free resp. silicone-free version, a factory calibration with calibration certificate and a customer specific configuration resp. preset is also optionally available like a material test certificate EN10204 3.1 or factory certifications for drink water resp. food suitability.

4_20mA_2_PNP Frontbuendig LED_Anzeige Druck Prozesstemperatur_125 Gehaese_Anzeige_drehbar
Auxiliary power
Supply voltage 10,5 V…35 V DC, reverse polarity protected
Supply current ≤ 60mA Analogue output
max. 22,5mA (Switch output with no load)
Switch output S1 / S2
Function PNP-switch to +L
Output current 0…≤ 200mA
current limited
short circuit protected
Analogue output – Power 4…20mA
Operating range 3,9mA…21mA
min. 3,8mA
max. 22mA
Permitted load ≤ (US – 10,5V) / 20mA
Start-up time ≤ 1 s
Measuring accuracy
Characteristic deviation ≤ ±0,5% FS
Long term drift ≤ ±0,2% FS/year, not cumulative
Temperature deviation ≤ ±0,02% FS/K (0°C…+80°C) (Measuring range ≤ 25bar)
≤ ±0,03% FS/K (+80°C…+125°C) (Measuring range ≤ 25bar)
≤ ±0,02% FS/K (-40°C…+100°C) (Measuring range ≥ 40bar)
≤ ±0,03% FS/K (+100°C…+125°C) (Measuring range ≥ 40bar)
Materials
Diaphragm
(process wetted)
Steel 1.4571 (316Ti)
Steel 1.4542 (630)
Steel 1.4534 (SI13800)
Process connection
(process wetted)
Steel 1.4571 (316Ti)
Connection housing CrNi-Steel
Gaskets
(process wetted)
NBR – nitrile-butadiene-rubber
FPM – fluorelastomere (Viton®)
EPDM – ethylene-propylene-dienmonomere, FDA-listed
Environmental conditions
Environmental temperature -40°C…+85°C
Process temperature -40°C…+125°C
Process pressure -1…+1000bar (depending on process connection)
Protection class IP65/IP67 (EN/IEC 60529)

Documentation german

User manual
Datasheet

Documentation english

User manual
Datasheet

Product configurator