{"id":4929,"date":"2016-03-14T14:08:37","date_gmt":"2016-03-14T13:08:37","guid":{"rendered":"http:\/\/www.acs-controlsystem.de\/news\/getrennte-ultraschall-fuellstandmessung-zur-sickerwasser-ueberwachung-von-kaplanturbinen\/"},"modified":"2021-07-21T08:09:55","modified_gmt":"2021-07-21T06:09:55","slug":"separate-ultrasonic-level-measurement-for-leachate-monitoring-of-kaplan-turbines","status":"publish","type":"news","link":"https:\/\/www.acs-controlsystem.de\/en\/news\/separate-ultrasonic-level-measurement-for-leachate-monitoring-of-kaplan-turbines\/","title":{"rendered":"Separate ultrasonic level measurement for leachate monitoring of Kaplan turbines"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row][vc_column]\n    <div class=\"spacer small\"><\/div>\n\n\n    [\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/2&#8243;][vc_column_text]<span>The power station Braunau-Simbach was the first power plant of the \u00d6sterreichisch-Bayerischen Kraftwerke AG and was built in the years 1951 &#8211; 54. The main building is above Simbach and Braunau at river Inn &#8211; km 61.1. The catchment area of the Inn at this point is 22.700km\u00b2. The weir and the power house are perpendicularly located to the flow axis in an alignment and dam the water level of the Inn at mean-flow conditions around 12,1m. The weir is located on the Bavarian and the power house on the Austrian side of the river. The power house is built in the usual design at the Inn without building construction. This design represents a particularly economical solution of river power plants construction. The capacity of this plant is 1.150m\u00b3 \/ s. (Source: \u00d6BK)<\/span>[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/2&#8243;]\n    <div class=\"spacer small\"><\/div>\n\n\n    [vc_single_image image=&#8221;1348&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221; onclick=&#8221;img_link_large&#8221; img_link_target=&#8221;_blank&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<span>In the power plant Braunau-Simbach 4 Kaplan turbines are installed with vertical shaft. Directly on the turbine shaft, a three-phase synchronous generator is arranged respectively. Each turbine has a throughput capacity of approximately 250 m\u00b3 \/ s. The maximum capacity is approximately 25.600kW.<\/span><\/p>\n<p><span>Because these turbines are at the heart of the power plant, they must be strictly monitored. The entry of leachate between the generator and turbine represents a serious threat not only to the Kaplan turbine but also for the entire machine area.<\/span>[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/2&#8243;]\n    <div class=\"spacer small\"><\/div>\n\n\n    [vc_single_image image=&#8221;1350&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221; onclick=&#8221;img_link_large&#8221; img_link_target=&#8221;_blank&#8221;][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_column_text]<\/p>\n<p class=\"bodytext\"><span>For this reason, these 4 spaces were provided with seperated ultrasonic sensors Sonicont USG of ACS-CONTROL-SYSTEM. These reliably detect the height or the occurrence of possible leachate.<\/span><\/p>\n<p class=\"bodytext\"><span>The corresponding transmitter Sonicont USF, which also serves as a display device, is mounted separately in the switch cabinet.<\/span><\/p>\n<p class=\"bodytext\"><span>Thus, the current state can always be recorded and monitored. This serves not only to simplify the read function, but also contributes to the safety of workers at the power plant, which would otherwise have to climb down \u00a0into the dangerous interspace.<\/span><\/p>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/2&#8243;]\n    <div class=\"spacer medium\"><\/div>\n\n\n    [vc_column_text]<\/p>\n<h4>Products used<\/h4>\n<p>[\/vc_column_text][vc_column_text]Ultrasonic sensor for level measurement in bulk solids and liquids Sonicont USG2[\/vc_column_text]\n    <div class=\"bld-position\" style=\"text-align: left\">\n        <a class=\"bld-btn rot\"            href=\"http:\/\/www.acs-controlsystem.de\/en\/produkte\/sonicont-usg2\/\">Sonicont USG2<\/a>\n    <\/div>\n\n\n    [vc_column_text]Transmitter and evaluation device with display Sonicont USF2[\/vc_column_text]\n    <div class=\"bld-position\" style=\"text-align: left\">\n        <a class=\"bld-btn rot\"            href=\"http:\/\/www.acs-controlsystem.de\/en\/produkte\/sonicont-usf2\/\">Sonicont USF2<\/a>\n    <\/div>\n\n\n    [\/vc_column][vc_column width=&#8221;1\/2&#8243;]\n    <div class=\"spacer medium\"><\/div>\n\n\n    [vc_column_text]<\/p>\n<h2>More information<\/h2>\n<p>[\/vc_column_text][vc_column_text]<span>You want to know more about leachate monitoring of kaplan turbines with separate ultrasonic level measurement?<\/span>[\/vc_column_text]\n    <div class=\"bld-position\" style=\"text-align: left\">\n        <a class=\"bld-btn rot\" target=\"_blank\"            href=\"http:\/\/www.acs-controlsystem.de\/produktkategorien\/visualisierung\/\">Anwendungsbericht<\/a>\n    <\/div>\n\n\n    [vc_column_text]<span>If you have any further questions, please feel free to contact our sales-team.\u00a0We can find the right solution for you, too!<\/span>[\/vc_column_text]\n    <div class=\"bld-position\" style=\"text-align: left\">\n        <a class=\"bld-btn rot\" target=\"_blank\"            href=\"http:\/\/www.acs-controlsystem.de\/en\/contact\/\">Contact<\/a>\n    <\/div>\n\n\n    [\/vc_column][\/vc_row][vc_row][vc_column]\n    <div class=\"spacer big\"><\/div>\n\n\n    [\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"featured_media":1349,"template":"","news-kategorie":[905],"class_list":["post-4929","news","type-news","status-publish","has-post-thumbnail","hentry","news-kategorie-aktion-en"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Separate ultrasonic level measurement for leachate monitoring of Kaplan turbines - ACS Control-System GmbH<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.acs-controlsystem.de\/en\/news\/separate-ultrasonic-level-measurement-for-leachate-monitoring-of-kaplan-turbines\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Separate ultrasonic level measurement for leachate monitoring of Kaplan turbines - ACS Control-System GmbH\" \/>\n<meta property=\"og:description\" content=\"[vc_row][vc_column][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/2&#8243;][vc_column_text]The power station Braunau-Simbach was the first power plant of the \u00d6sterreichisch-Bayerischen Kraftwerke AG and was built in the years 1951 &#8211; 54. The main building is above Simbach and Braunau at river Inn &#8211; km 61.1. The catchment area of the Inn at this point is 22.700km\u00b2. The weir and the power house &hellip; Continue reading &quot;Separate ultrasonic level measurement for leachate monitoring of Kaplan turbines&quot;\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.acs-controlsystem.de\/en\/news\/separate-ultrasonic-level-measurement-for-leachate-monitoring-of-kaplan-turbines\/\" \/>\n<meta property=\"og:site_name\" content=\"ACS Control-System GmbH\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=100046272027146\" \/>\n<meta property=\"article:modified_time\" content=\"2021-07-21T06:09:55+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.acs-controlsystem.de\/wp-content\/uploads\/Fuellstand_Applikationsbeispiele_Kraftwerk_USG_USF_1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"539\" \/>\n\t<meta property=\"og:image:height\" content=\"227\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@ACS_Control_Sys\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Separate ultrasonic level measurement for leachate monitoring of Kaplan turbines - ACS Control-System GmbH","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.acs-controlsystem.de\/en\/news\/separate-ultrasonic-level-measurement-for-leachate-monitoring-of-kaplan-turbines\/","og_locale":"en_US","og_type":"article","og_title":"Separate ultrasonic level measurement for leachate monitoring of Kaplan turbines - ACS Control-System GmbH","og_description":"[vc_row][vc_column][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/2&#8243;][vc_column_text]The power station Braunau-Simbach was the first power plant of the \u00d6sterreichisch-Bayerischen Kraftwerke AG and was built in the years 1951 &#8211; 54. The main building is above Simbach and Braunau at river Inn &#8211; km 61.1. The catchment area of the Inn at this point is 22.700km\u00b2. The weir and the power house &hellip; Continue reading \"Separate ultrasonic level measurement for leachate monitoring of Kaplan turbines\"","og_url":"https:\/\/www.acs-controlsystem.de\/en\/news\/separate-ultrasonic-level-measurement-for-leachate-monitoring-of-kaplan-turbines\/","og_site_name":"ACS Control-System GmbH","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=100046272027146","article_modified_time":"2021-07-21T06:09:55+00:00","og_image":[{"width":539,"height":227,"url":"https:\/\/www.acs-controlsystem.de\/wp-content\/uploads\/Fuellstand_Applikationsbeispiele_Kraftwerk_USG_USF_1.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@ACS_Control_Sys","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.acs-controlsystem.de\/en\/news\/separate-ultrasonic-level-measurement-for-leachate-monitoring-of-kaplan-turbines\/","url":"https:\/\/www.acs-controlsystem.de\/en\/news\/separate-ultrasonic-level-measurement-for-leachate-monitoring-of-kaplan-turbines\/","name":"Separate ultrasonic level measurement for leachate monitoring of Kaplan turbines - ACS Control-System GmbH","isPartOf":{"@id":"https:\/\/www.acs-controlsystem.de\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.acs-controlsystem.de\/en\/news\/separate-ultrasonic-level-measurement-for-leachate-monitoring-of-kaplan-turbines\/#primaryimage"},"image":{"@id":"https:\/\/www.acs-controlsystem.de\/en\/news\/separate-ultrasonic-level-measurement-for-leachate-monitoring-of-kaplan-turbines\/#primaryimage"},"thumbnailUrl":"https:\/\/www.acs-controlsystem.de\/wp-content\/uploads\/Fuellstand_Applikationsbeispiele_Kraftwerk_USG_USF_1.jpg","datePublished":"2016-03-14T13:08:37+00:00","dateModified":"2021-07-21T06:09:55+00:00","breadcrumb":{"@id":"https:\/\/www.acs-controlsystem.de\/en\/news\/separate-ultrasonic-level-measurement-for-leachate-monitoring-of-kaplan-turbines\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.acs-controlsystem.de\/en\/news\/separate-ultrasonic-level-measurement-for-leachate-monitoring-of-kaplan-turbines\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.acs-controlsystem.de\/en\/news\/separate-ultrasonic-level-measurement-for-leachate-monitoring-of-kaplan-turbines\/#primaryimage","url":"https:\/\/www.acs-controlsystem.de\/wp-content\/uploads\/Fuellstand_Applikationsbeispiele_Kraftwerk_USG_USF_1.jpg","contentUrl":"https:\/\/www.acs-controlsystem.de\/wp-content\/uploads\/Fuellstand_Applikationsbeispiele_Kraftwerk_USG_USF_1.jpg","width":539,"height":227},{"@type":"BreadcrumbList","@id":"https:\/\/www.acs-controlsystem.de\/en\/news\/separate-ultrasonic-level-measurement-for-leachate-monitoring-of-kaplan-turbines\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.acs-controlsystem.de\/en\/"},{"@type":"ListItem","position":2,"name":"Separate ultrasonic level measurement for leachate monitoring of Kaplan turbines"}]},{"@type":"WebSite","@id":"https:\/\/www.acs-controlsystem.de\/#website","url":"https:\/\/www.acs-controlsystem.de\/","name":"ACS Control-System GmbH","description":"Your partner for measurement and automation","publisher":{"@id":"https:\/\/www.acs-controlsystem.de\/#organization"},"alternateName":"ACS Control-System","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.acs-controlsystem.de\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.acs-controlsystem.de\/#organization","name":"ACS-Control-System GmbH","alternateName":"ACS Contrtol-System","url":"https:\/\/www.acs-controlsystem.de\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.acs-controlsystem.de\/#\/schema\/logo\/image\/","url":"https:\/\/www.acs-controlsystem.de\/wp-content\/uploads\/logo.png","contentUrl":"https:\/\/www.acs-controlsystem.de\/wp-content\/uploads\/logo.png","width":2000,"height":1500,"caption":"ACS-Control-System GmbH"},"image":{"@id":"https:\/\/www.acs-controlsystem.de\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/profile.php?id=100046272027146","https:\/\/x.com\/ACS_Control_Sys"]}]}},"_links":{"self":[{"href":"https:\/\/www.acs-controlsystem.de\/en\/wp-json\/wp\/v2\/news\/4929","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.acs-controlsystem.de\/en\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/www.acs-controlsystem.de\/en\/wp-json\/wp\/v2\/types\/news"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.acs-controlsystem.de\/en\/wp-json\/wp\/v2\/media\/1349"}],"wp:attachment":[{"href":"https:\/\/www.acs-controlsystem.de\/en\/wp-json\/wp\/v2\/media?parent=4929"}],"wp:term":[{"taxonomy":"news-kategorie","embeddable":true,"href":"https:\/\/www.acs-controlsystem.de\/en\/wp-json\/wp\/v2\/news-kategorie?post=4929"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}