Flow measurements Water/wastewater management

All sensors are state of the art, certified and easy to install and commission.

The Flowcont® FN has a wide selection of process connections, nominal sizes and highly resistant linings up to 180°C.
The innovative transducer has a short response time due to its high excitation frequency. Modern filtering methods allow measurement signals and interference signals to be precisely separated.

This enables highly accurate measurement even under difficult conditions. Self-cleaning electrodes with double sealing guarantee high reliability of the flow meter.

Thanks to the grid-reinforced PFA lining, the appliance is vacuum-stable and can be used up to 180°C. Flowcont® FN is the device standard in the process industry. It fulfills the various requirements of NAMUR. Flowcont® FN is the universal device as defined by the Pressure Equipment Directive. In accordance with the requirements of NAMUR, pipelines are rated according to category III. This makes the Flowcont® FN universally applicable. Costs are reduced, safety is increased.

Application

  • Intuitive operation: Softkey functionality; “Easy Set-up” function
  • Touch-free operating keys: Parameterization of the device without opening the housing
  • Practice-oriented diagnostics: Status messages according to NAMUR; help texts in the display
  • Highest measurement accuracy: Maximum measurement deviation: 0.2 % of measured value
  • Universal transmitter: Reduces spare parts inventory and storage costs
  • State-of-the-art memory technology in the transducer: avoids errors and makes commissioning fast and safe.
  • Approvals for explosion protection: according to ATEX, IECEx; according to FM, cFM, NEPSI, GOST
  • HART, PROFIBUS PA, FOUNDATION Fieldbus: access to all status information

Operating principle

The FLOWCONT FN flowmeter operates on the magnetic inductive measuring principle.
A magnetic field is generated in the measuring tube of the flow meter and the voltage of the electrically conductive liquid is measured via electrodes.
The output signals are the flow velocity in the pipe as an analog output (4 – 20mA) and the flow rate as pulses (l / hl / m3).

Measuring ranges

Measuring medium:

Flüssigkeiten

Process temperature:

-40°C bis 200°C

Conditions:

Chemisch beständig, Trinkwasser geeignet, Korrosionsbeständig

Recommended product

Flowcont® F630
  • Durch eine Vielzahl an Varianten, für jeden Anwendungsfall das richtige Gerät
  • Getrennte Version möglich
  • ATEX-Zulassung

Measuring ranges

Measuring medium:

Flüssigkeiten

Conditions:

Chemisch beständig, Trinkwasser geeignet, Korrosionsbeständig

Recommended product

Flowcont® L630
  • Hygenene applications
  • Error diagnosis system
  • Free passage in the measuring tube

Measuring ranges

Measuring medium:

Flüssigkeiten

Recommended product

Fluxicont® FS4
  • Anwendung im Hygienebereich möglich
  • Verschleißfrei