Precont® PS4SC

Delivery Time: not specified

Pressure switch for supervision of absolute and relative pressures in gases, vapors, liquids and dust

  • Highly accurate and long-term stable ceramic measuring cell
  • Many variants of flush process connections
  • Bright LED display

 

Description

Due to the device construction as well as the availability of a variety of hygienic resp. standard process connections the device Precont® PS4SC is especially suitable for the use for hygienic and aseptic applications in food and beverage industry, pharmaceutical industry, biotechnology and sterile process engineering as well as general applications in machinery and plant engineering, air-conditioning and refrigeration plant engineering, hydraulic and pneumatic systems, process industry and environmental technology.

The pressure switch is suitable for demanding measuring requirements.

Due to its high accuracy and the high flexibility of configuration, the device can be suited a wide variety of applications.

The pressure switch with front-flush diaphragm has been specifically designed for the measurement of viscous, paste-like, adhesive, crystallizing, particle-laden and contaminated media, which would clog the pressure channel of conventional process connections.

The front-flush diaphragm is completely welded with the process connection and supplied with a positive seal. A reliable, dead-space free sealing between the process connection and the process adapter resp. measuring medium is thus assured.

The robust design and the high-quality workmanship turns the device into a very high quality product, which even the most adverse environmental conditions cannot affect, whether the lowest temperatures when used outdoors, extreme shock and vibration or aggressive media.

A captive laser marking of the type label ensures the identifiability throughout the entire lifetime of the device. Obviously is the optional marking of a measurement point designation resp. TAG, a customer label or of a neutral type label, of course also per laser marking.

A LABS-free resp. silicone-free version, a factory calibration with calibration certificate and a customer specific configuration resp. preset is also optionally available like a material test certificate EN10204 3.1 or factory certifications for drink water resp. food suitability.

4_20mA_2_PNP LED_Anzeige Ansprechzeit Bedienoberfläche 4_20mA_2_PNP Gehaese_Anzeige_drehbar
Auxiliary power
Supply voltage 10,5 V…30 V DC, reverse polarity protected
Supply current ≤ 60mA Analogue output
max. 22,5mA (Switch output with no load)
2 x PNP-switch output
Function PNP-switch to +L
Output current 0…≤ 200mA
current limited,
short circuit protected
Analogue output- Power 4…20mA
Operating range 3,9mA…21mA
min. 3,8mA
max. 22mA
Permitted load ≤ (US – 10,5V) / 20mA
Start-up time ≤ 1ms
Measuring accuracy
Characteristic deviation ≤ ±0,2% FS
Long term drift ≤ ±0,1% FS/year, not cumulative
Temperature deviation Zero: ≤ ±0,015% FS/K, max. ±0,75% (-20°C…+80°C)
Span: ≤ ±0,015% FS/K, max. ±0,5% (-20°C…+80°C / > 400mbar)
Span: ≤ ±0,015% FS/K, max. ±0,8% (-20°C…+80°C / ≤ 400mbar)
Materials
Diaphragm
(process wetted)
Ceramik Al2O3 96%
Ceramik Al2O3 99,7%
Ceramik Al2O3 99,9%
Process connection
(process wetted)
Steel 1.4404 (316L)
Steel 1.4571 (316Ti)
Connection housing CrNi-Steel
Gaskets
(process wetted)
FPM – fluorelastomere (Viton®)
EPDM – ethylene-propylene-dienmonomere, FDA-listed
FFKM – perfluorelastomere (e.g. Kalrez®)
FFKM hd – perfluorelastomere high density
Environmental conditions
Environmental temperature -40°C…+85°C
Process temperature -40°C…+125°C
Process pressure -1…+60bar (depending on process connection)
Protection class IP65/IP67 (EN/IEC 60529)

Documentation german

User manual
Datasheet

Documentation english

User manual
Datasheet

Product configurator