Conductive compact probes KAK/KLK

Delivery Time: not specified

KAK for standard applications; KLK for food applications

Limit switch or two point controller

  • Intergrated processor
  • Different process connections for hyginic applications
  • Different electronics

 

Categories: , ,

Description

The filling level limit switch KAK resp. KLK is used, to evaluate one or two filling levels resp. limit levels in electrically conductive liquids with a conductivity of minimum 5µS/cm resp. a resistance of maximum 200kOhm.
The device is also useable as overflow protection in container with liquids, for the realization of a two-position-control e.g. for pump control or also as dry run protection.
The conductivity also of aggressive filling liquids can be detected, at process temperatures from -40 °C to +100 °C, at pressures from -1 bar to +10 bar.
The version KAK is the standard type for general applications, whereas the version KLK is especially conceived for food applications.

 

Function
The sensor electrodes or the connection screw of the fill level limit switch KLK, that represents the electrodes in the container, that needs to be controlled, are connected to the integrated electronic module. In metal containers the wall can be used as ground electrode by using the electrical contact of the connection screw with the container wall. An alternating voltage of approx. 9 V is applied to the electrodes. Because of this, touching the electrodes is absolutely safe. If the electrically conductive fill liquid contacts the electrodes, a small alternating current flows between the electrodes. Limiting the current to a value less than 1,5 mA largely avoids an electrolytically decomposition of the fill liquid. In a 2-point-control the PNP switching output or the relay output is switched on, if the minimum and the maximum electrode are connected by the fill liquid and switches only back if the fill liquid connects non of the two electrodes. In this application, the longest electrode represents the ground electrode, the next longest rod the minimum electrode and the shortest rod the maximum electrode. In a 1-point-control (limit value detection) the device works only with the ground and the maximum electrode. The PNP switching output or the relay output switches on, if the fill liquid makes an conductive connection between ground and maximum electrode and switches only back, if there is no more connection between the two electrodes. A flapping of the relay, due to a wave motion of the fill liquid is suppressed because the sensor relay principally switches with an time delay of approx. 1,5 seconds. At the front for the device, the sensitivity of the sensor can be adjusted exactly using a 10-turn-potentiometer. As function of the sensor minimum or maximum protection function can be chosen.

Druck_bis_10 AC_DC 4_20mA_2_PNP Empfindlichkeit CIP_SIP
Betriebsdruck max. -1bar … +10bar
Mediumstemperatur -40°C…+100°C
Schutzart IP65 DIN EN 60529
Werkstoffe
Dichtungen FPM (bei Variante KAK)
EPDM/FDA gelistet (bei Variante KLK)
Prozessanschluss Stahl 1.4571 (AISI 316L)
Stahl 1.4404 (AISI 316 Ti)
Sondenstab Stahl 1.4571 (AISI 316L)
Stahl 1.4404 (AISI 316 Ti)
Hastelloy B4/C22
Titan
Isolation Sondenstab PA/ETFE/E-CTE (bei Variante KAK)
ETFE/FDA gelistet (bei Variante KLK)

Dokumentation deutsch

Bedienungsanleitung
Datenblatt

Dokumentation englisch

Bedienungsanleitung
Datenblatt

Product configurator

    Edelstahl 1.4404

    Länge L1 (Sondenstab 2) in mm

    Länge L1 (Sondenstab 3) in mm

    Text der Laserbeschriftung