Precont® PU4SK

Delivery Time: not specified

Pressure transmitter for general applications and monitoring of absolute or relative pressure in gases, vapors, liquids and dust – even from harzadous areas

  • Ceramic measuring cell for measuring ranges up to 600 bar
  • short response time <2ms
  • Electronics versions with HART, IO-Link and Modbus

 

Description

The device Precont® PU4SK is an electronic pressure transmitter / pressure switch for monitoring, control and continuous measurement of pressures.

A high variety of versions of process connections and electronic types allows the use for a wide range of applications, also for demanding measuring requirements.

The front-flush process connection enables the cleanability of the wetted diaphragm to be integrated into the process, also by SIP cleaning processes.

Low-maintenance and trouble-free pressure measurement is thus also guaranteed in critical applications with viscose or also frequently changing media.

Due to its high accuracy and the digital adjustability by HART®, RS485 Modbus®-RTU or IO-Link® the device Precont® PU4SK can be suited to a wide variety of applications.

The robust design and the high-quality workmanship turns the device into a very high quality product, which even the most adverse environmental conditions cannot affect, whether the lowest temperatures when used outdoors, extreme shock and vibration stress or aggressive media.

A captive laser marking of the type label ensures the identifiability throughout the entire lifetime of the device.

Obviously is the optional marking of a measurement point designation resp. TAG, a customer label or of a neutral type label, of course also per laser marking.

A LABS- resp. silicone-free version, a factory calibration with calibration certificate and a customer specific configuration resp. preset is also optionally available like a material test certificate EN10204 3.1 or a factory certifications for drink water suitability.

Customer specific special versions can be realized short-term on request, e.g. special designs for the process connection or other process materials.

Druck_bis_600 Prozesstemperatur_135_en Ex_Zulassung Schutzart_IP69K_en Genauigkeit_0_15 Ansprechzeit
Messbereich
Nenndruck PN -1bar bis 0bar bis 0bar bis +600bar
-1bar bis +1bar bis 0bar bis +600bar
0bar bis 0,25bar bis 0bar bis +600bar
Ausgang Typ A – Strom 4 bis 20mA HART®
Analogausgang 4 bis 20mA 3,9mA bis 20,5mA
≥ 3,8mA
≤ 22mA
dI ≤ 1µA
Zeitverhalten T90 ≤ 5ms
ton ≤ 0,2s
Schnittstelle HART®-konform (7.0)
1200 Bit/s
Ausgang Typ V – RS485 Modbus®-RTU
Schnittstelle RS485, bidirektional
Modbus®-RTU
9600 Baud (4800 bis 38400 Baud)
Zeitverhalten T90 ≤ 2ms
ton ≤ 0,1s
Ausgang Typ L – IO-Link®
Schnittstelle IO-Link® V1.1
Com2 (38400 Baud)
Analogausgang 0mA bis 20,5mA (bei 0 bis 20mA)
≤ 0,05mA (bei 0 bis 20mA)
≤ 22mA (bei 0 bis 20mA)
dI ≤ 1µA (bei 0 bis 20mA)
3,8mA bis 20,5mA (bei 4 bis 20mA)
≥ 3,6mA (bei 4 bis 20mA)
≤ 22mA (bei 4 bis 20mA)
dI ≤ 1µA (bei 4 bis 20mA)
Schaltausgang 2x PP (Push-Pull)
Schaltend auf +L/-L
Ausgang Uout ≤ 0,2V ≥ Us – 2V
Iout = 0mA bis 200mA
Zeitverhalten T90 ≤ 2ms
ton ≤ 0,1s
Hilfsenergie
Versorgungsspannung Us
(verpolungsgeschützt)
9 V bis 35 V DC (bei Elektronik-Ausgang Variante A)
9 V bis 30 V DC (Ex) (bei Elektronik-Ausgang Variante A)
6 V bis 35 V DC (bei Elektronik-Ausgang Variante V)
9 V bis 35 V DC (bei Elektronik-Ausgang Variante L ohne IO-Link®)
18 V bis 30 V DC (bei Elektronik-Ausgang Variante L mit IO-Link®)
Messgenauigkeit
Kennlinienabweichung ≤ ±0,15% FSO
≤ ±0,5%FSO
Langzeitdrift ≤ ±0,2% FSO/Jahr
Temperaturabweichung Tk Nullpunkt ≤ ±0,05% FSO/K
Prozessbedingungen
Prozesstemperatur Standard: -40°C bis +100°C
Erweitert: -40°C bis +135°C (140°C bis zu 1h lang)
Druckzyklen ≥ 100Mio. (1,2xPN)
Umgebungsbedingungen
Umgebungstemperatur -40°C bis +100°C
Schutzart IP69K/IP67 (EN/IEC 60529)
MTTF 463 Jahre