Rod probe SAT
With synthetic thread
With up to 7 probe systems, Fluid Temperature: -40°C … 150°C
- Simple installation and setup
- Up to 6 measuring points
- ATEX-approval
Description
The SAT rod probes are used in conjunction with the evaluation units (eg, SRA-100-U0) is used for level detection and level control in conductive liquids.
Depending on the number of bars and evaluation devices used, different measurement tasks such as Overflow, dry run, two-step control, moisture detection, etc. are realized.
Depending on model selected can include the container wall as a mass, to be implemented to 7 switch points. The ground connection erflogt either directly to the container or conducting a probe rod.
In the probe head, an additional module (diode module LBM) for permanent circuit monitoring to be installed.
In the case of a line break between the electrode probe and an appropriate evaluation, the evaluation issue an alert.






Process pressure max. | -1bar … +10bar |
---|---|
Process temperature | -40°C…+150°C |
Protection class | IP65 EN/IEC 60529 |
Material Process connection | POM PP PTFE |
Material Electrode rod | Steel 1.4404 (AISI316L) Steel 1.4571 (AISI316TI) Hastelloy C22 |
Isolation Electrode rod isolation | PA ETFE E-CTFE |
Gaskets (medium contact) |
NBR (Electrode isolation PA) FPM (Electrode isolation ETFE/E-CTFE) |
Product configurator
- €
- €
- €
- €
- €
- €
- €
- €
Elektrodenstab 1
- €
- €
- €
Elektrodenstab 2
- €
- €
- €
Elektrodenstab 3
- €
- €
- €
Elektrodenstab 4
- €
- €
- €
Elektrodenstab 5
- €
- €
- €
Elektrodenstab 6
- €
- €
- €